Kunitomi, Kazuhiko; Katanishi, Shoji; Takada, Shoji; Takizuka, Takakazu; Yan, X.; Kosugiyama, Shinichi
JSME International Journal, Series B, 47(2), p.261 - 267, 2004/05
The GTHTR300 aiming at electric generation with its thermal efficiency of 46 % is a safe and economically competitive HTGR in 2010s. A helium gas turbine system connected with the reactor is designed based on existing technologies developed for fossil gas turbine systems. However, there are some uncertainties in performance of a helium gas compressor, electric magnetic bearings and control system. In order to confirm these technical uncertainties, a 1/3 scale model of the compressor and 1/3 scale magnetic bearings will be manufactured and tested in the simulated condition of the GTHTR300. This paper describes R&D plans focusing on the 1/3 scale compressor model test as well as unique design features of the GTHTR300.